New

Revolutionary Salter Labs High Flow Oxygen Humidifier Bottle – Embrace Soothing, Moisturized Oxygen Therapy

0.000.00

Description

Discover the Salter Labs High Flow Oxygen Humidifier Bottle for Superior Respiratory Comfort

Elevate your oxygen therapy with the Salter Labs High Flow Oxygen Humidifier Bottle, engineered to deliver precisely humidified oxygen at flow rates up to 15 L/min. Whether you’re receiving in-home oxygen via concentrator or cylinder, this premium humidifier bottle ensures warm, moisture-rich gas—preventing dryness, irritation, and discomfort—so you can breathe easy and live life to the fullest.


1. Precision Humidification for High Flow Oxygen Therapy

  • High Flow Compatibility
    Specifically designed for oxygen flow rates from 1 to 15 L/min, the Salter Labs bottle handles even the highest prescribed flows without risk of boiling or under-humidification.

  • Adjustable Humidity Control
    Fine-tune moisture output by varying the water level and system temperature. Achieve optimal comfort whether you require gentle moisture at low flows or robust humidification at high flows.


2. Robust Construction & Safety Features

  • Medical-Grade Materials
    Constructed from BPA-free, PVC-free polymers, the bottle resists chemical degradation and is 100% biocompatible—ensuring safe, contaminant-free humidification.

  • Anti-Spill Design
    The secure, locking cap and internal baffle prevent water from spilling into tubing or oxygen ports, even if the bottle is accidentally tipped or subjected to movement.

  • Universal Connection Port
    The threaded inlet fits standard 22 mm oxygen outlet fittings, and the outlet nozzle accepts all 22 mm tubing—no adapters required.


3. Benefits That Enhance Every Breath

  1. Improved Mucosal Comfort
    Warm, moist oxygen helps maintain mucociliary function, reducing nasal dryness, cavitary crusting, and throat irritation common with unhumidified high-flow therapy.

  2. Enhanced Patient Compliance
    Comfortable humidification increases therapy tolerance—patients are more likely to adhere to prescribed oxygen regimens when they breathe comfortably.

  3. Reduced Respiratory Complications
    Proper humidification decreases the risk of airway inflammation, coughing, and infection associated with dry gas delivery.

  4. Easy Monitoring & Refilling
    The transparent bottle body and graduated markings allow quick visual checks of water level; refilling is a simple twist-off, refill-and-relock process.

  5. Cost-Effective Maintenance
    Durable construction withstands repeated cleaning and sterilization. Replace the disposable bottle every 6–12 months to ensure consistent performance.


4. How to Set Up Your Salter Labs Humidifier Bottle

  1. Fill with Sterile or Distilled Water
    – Unscrew the top cap and fill up to the indicated “Max” fill line. Avoid mains tap water to minimize mineral deposits.

  2. Attach to Oxygen Source
    – Screw the inlet port onto your oxygen concentrator’s humidifier outlet or cylinder flowmeter until snug.

  3. Connect Oxygen Tubing
    – Push your 22 mm oxygen tubing onto the bottle’s outlet nozzle until it clicks. Ensure no kinks exist in the tubing.

  4. Power On & Adjust Flow
    – Turn on the oxygen source and set prescribed flow. Listen for smooth bubbling—this indicates proper humidification.

  5. Verify Performance
    – Check for consistent, gentle bubbling and inspect tubing for moisture. Adjust water level or source temperature if necessary for comfort.


5. Care & Maintenance for Longevity

  • Daily Rinse
    Empty residual water each morning. Rinse the bottle interior with warm water and shake out droplets. Air-dry upside down.

  • Weekly Deep Clean
    Soak in a solution of one part white vinegar to three parts water for 15 minutes to remove mineral buildup. Rinse thoroughly with sterile or distilled water and air-dry.

  • Monthly Inspection
    Check for cracks, cloudiness, or discoloration. Replace the bottle every 6–12 months—or sooner if signs of wear appear—to maintain safe, hygienic operation.


6. Frequently Asked Questions

Q: Can I use boiled tap water if I don’t have distilled?
A: If distilled water is unavailable, boiled and cooled tap water can be used once. However, distilled water is recommended to minimize mineral deposits and prolong bottle life.

Q: Will this humidifier work with my CPAP tubing?
A: The Salter Labs humidifier bottle is intended for oxygen therapy only. Do not connect CPAP tubing directly—use only with prescribed oxygen equipment.

Q: How do I prevent “rain-back” into the oxygen source?
A: Ensure proper vertical orientation, maintain recommended water level, and avoid excessive condensation by keeping the room at moderate temperature (18–22 °C).

Q: Is sterilization required?
A: The bottle can be sterilized using standard medical-grade disinfection solutions. Follow your facility’s protocols for cleaning and sterilization.

Reviews

There are no reviews yet.

Be the first to review “Revolutionary Salter Labs High Flow Oxygen Humidifier Bottle – Embrace Soothing, Moisturized Oxygen Therapy”

Your email address will not be published. Required fields are marked *

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare
0
    0
    Your Cart
    Your cart is emptyReturn to Shop